MONTHLY HOIST ROPE INSPECTION REPORT
DEFICIENCIES TO LOOK FOR
Rope Diameter_____________
1 OK__Bad__In running ropes, twelve randomly distributed broken wires in one lay or four broken wires in one stand in one lay.
2 OK__Bad__One or more outer wire at the contact point with the core of the rope which has worked its way out of the rope structure and protrudes or loops out from the rope structure.
3 OK__Bad__Wear of 1/3 the original diameter of outside individual wires.
4 OK__Bad__Kinking, crushing, bird caging, or any other damage resulting in distortion of the rope structure.
5 OK__Bad__Evidence of heat/chemical damage .
6 OK__Bad__Reduction from nominal diameter greater than those listed in the Maximum Allowable Reduction Table.
7 OK__Bad__Attention shall be given to end connections. Upon development of two broken wires adjacent to a soceked end connection, the rope should be resocketed or replaced. Resocketing shall not be attempted if the resulting rope length will be insufficient for proper operations.
8 OK__Bad__Replacement rope and connections shall have a strength rating at least as great as the original rope and connections furnished by the hoist manufacturer. Any deviation from the original size, grade, or construction shall be specified by a rope manufacturer, the hoist manufacturer, or a qualified person.
9 OK__Bad__In standing ropes, more than two wires in one lay in sections beyond end connections or more than one broken wire in one lay at an end connection.
Project Name: |
Project Location: |
Inspected By: |
Date: |
Type of Crane & Capacity |
Equipment # |
Serial #: |
Project Name______________________
Inspected By_______________________
Equipment #_______________________
Project Location____________________
TypeofCrane & Capacity _________________________________
Serial#___________________________
Date_____________________________